ERM 200/60-3: parallelepiped in shape, this electromagnetic bar holds a ferromagnetic part in place by closing the magnetic field around the poles of the part to be held. When the bar coil is not powered, the electromagnetic force is canceled and the ferromagnetic part is released.
Holding magnets
Product range
Electromagnetic bar
Product range
Electromagnetic bar
Protection index
IP65
Thickness of counter plates
3
Thickness of counter plates
3 mm
Air gap force zero
1130
Air gap force zero
1130 N
Air gap force 0.1 mm
990
Air gap force 0.1 mm
990 N
Air gap force 0.2 mm
890
Air gap force 0.2 mm
890 N
Holdingmagnet connection
DIN connector
Insulation class of the holdingmagnet
B
Standard voltage of the suction cups
24
Standard voltage of the suction cups
24 V
Duty cycle of the holdingmagnet
100 %
Duty cycle of the holdingmagnet
100
Power of the holdingmagnet
40
Power of the holdingmagnet
40 W
Holdingmagnets options
Other voltages and duty factors on request. Note: When the suction pads or bars are used for handling, it will be necessary to choose a safety factor of 3 on the force and to take note of the technica