86 021 06E Brakes and clutches

Clutch by energizing

Clutch by energizing

86 021 06E: this clutch by energizing has the following characteristics: -clutching by energizing -coupling without current -angular clearance almost zero when stopped -couple residual uncoupled zero (in all mounting positions) -allows the clutch with relative speed through a mixed friction lining.
Brakes and clutches
Grayed out functions require you to be logged in to your account
login to my account
Product range
Clutch by energizing
Fastening
By flange
Dimension d3
42
Dimension d3
42 mm
Weight without member
0,35
Weight without member
0,35 kg
Air gap S0
0,2
Air gap S0
0,2 mm
Dimension d2
6*20
Dimension d2
6*20 mm
Dynamic torque M2
2,2
Dynamic torque M2
2,2 N⋅m
Lifetime (indicative values) MJ
120
Lifetime (indicative values) MJ
120 MJ
Dimension b4
12
Dimension b4
12 mm
Moment of inertia of the armature without hub
0,22
Moment of inertia of the armature without hub
0,22 kg/cm²
Dimension b6
2
Dimension b6
2 mm
Dimension d9
48
Dimension d9
48 mm
Moment of inertia of the rotating polar armature
0,55
Moment of inertia of the rotating polar armature
0,55 kg/cm²
Dimension b7
56
Dimension b7
56 mm
Dimension d10
65
Dimension d10
65 mm
Dimension d11
4,5
Dimension d11
4,5 mm
Dimension d12
75,5
Dimension d12
75,5 mm
Dimension b
19
Dimension b
19 mm
Dimension b2
2
Dimension b2
2 mm
Dimension d
56
Dimension d
56 mm
Dimension L
400
Dimension L
400 mm
Dimension ?
4*90°
Other characteristics
To ensure its function, the device must be mounted with a mobile armature 86 XXX ... B200 or 86 XXX ... B300 (more details in the catalog for download).
Dimension d1
53
Dimension d1
53 mm
Dimension M
6*M3*4
Dimension M
6*M3*4 mm
Dimension b3
4
Dimension b3
4 mm
Dimension ?
6*60°
Dimension ?
30°
Product range
Clutch by energizing
Maximum speed nmax
10000
Maximum speed nmax
10000 min⁻¹
Permissible friction work per hour P max
160
Permissible friction work per hour P max
160 kJ/h
Permissible friction work per operation W max
4,5
Permissible friction work per operation W max
4,5 kJ
Response time for breaking t2
18
Response time for breaking t2
18 ms
Nominal voltage
24
Nominal voltage
24 VDC
Power rating
10
IP protection
IP 00
Connection
Free wires
Insulation class
F